INITIAL SET-UP:
1. Read safety warnings before setting-up air compressor.
2. Ensure the oil level in the air compressor pump is adequate. The oil level should be at the center of the oil sight
glass.
If low, add Senco
®
part number PC0344 compressor pump oil.
LOCATION:
CAUTION
In order to avoid damaging the air compressor, do not incline the air compressor transversely
or longitudinally more than 10°.
1. Place air compressor at least 12 inches away from obstacles that may prevent proper ventilation. Do not
place air compressor in an area:
-where there is evidence of oil or gas leaks.
-where flammable gas vapors or materials may be present.
WARNING
Serious injury or death may occur if electrical sparks from motor and pressure switch come
in contact with flammable vapors, combustible dust, gases or other combustible materials.
When using the air compressor for spray painting, place the air compressor as far away from
the work area as possible, using extra air hoses instead of extension cords.
-where air temperatures fall below 32°F or exceed 104°F.
-where extremely dirty air or water could be drawn into the air compressor.
ELECTRICAL:
DANGER
Improper connection of the equipment-grounding conductor can result in a risk of shock or
electrocution. Check with a qualified electrician or service personnel if you are in doubt as
to whether the outlet is properly grounded. Do not use any type of adapter with this product.
If repair or replacement of the cord or plug is necessary, do not connect the grounding wire
to either flat blade terminal. The wire with insulation having an outer surface that is green
with or without yellow stripes is the grounding wire.
PREPARATION
WARNING
This product must be grounded. If there should be a malfunction or breakdown, grounding
provides a path of least resistance for electric current to reduce the risk of electric shock.
This product is equipped with a cord having an equipment-grounding conductor and a
grounding type plug. The plug must be plugged into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.
1. Senco
®
DOES NOT RECOMMEND THE USE OF EXTENSION CORDS as this can create power loss and
overheating of the motor. Use of an additional air hose is recommended rather than an extension cord. If
use of an extension cord is unavoidable, it should be plugged into a GFCI found in circuit boxes or protected
receptacles. When using an extension cord, observe the following:
Cable Length Wire Gauge
Up to 25 feet 12 AWG
Up to 100 feet 10 AWG
Up to 150 feet 8 AWG
Up to 250 feet 6 AWG
Use only 3-blade extension cords that have 3-blade grounding-type plugs and 3-slot cord connectors that will
accept the plug from the product. Use only extension cords having an electrical rating not less than the rating
of the product. Do not use damaged extension cords. Examine extension cord before using and replace if
damaged. Do not abuse extension cord and do not yank on any cord to disconnect. Keep cord away from heat
and sharp edges. Always shut off the air compressor switch before removing the plug from the receptacle.