OPERATION
PRE-START CHECKLIST:
1. Check oil level. Add if necessary.
2. Remove any moisture in the air compressor air tank. Remove excessive pressure with an air tool, then open
the air tank drain valve in the bottom of the air tank. Close tightly when drained.
WARNING: Risk of bodily injury. NEVER attempt to open the drain valve when
more than 10 PSI of air pressure is in the air tank!
3. Make sure the air compressor Motor Switch is in the “OFF” position.
4. Make sure all safety valves are working correctly.
5. Make sure all guards and covers are in place and securely mounted.
6. Make sure that air filter is placed in proper opening. Remove plug before threading housing into compressor.
START-UP:
1. Ensure the lever on the pressure switch box is in the “OFF” position.
2. Plug the power cord into a grounded outlet.
3. Move the lever on the pressure switch box to the “ON” position.
5. Set pressure by adjusting the pressure regulator knob counterclockwise for less pressure and clockwise for
more pressure.
6. If you notice any unusual noise or vibration, stop the air compressor and refer to “Troubleshooting”.
SHUTDOWN:
1. To stop the air compressor, move the lever on the pressure switch box to the “OFF” position. NEVER stop the
air compressor by unplugging it from the power source. This could result in risk of electrocution.
2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve rings.
3. Once pressure in the air tanks register under 10 psig, open the drain valve under each air tank to drain any
moisture.
4. Allow the air compressor to cool down.
5. Wipe air compressor clean and store in a safe, non-freezing area.
MAINTENANCE
Read the instruction manual before performing maintenance. The following procedures must be performed when
stopping the air compressor for maintenance or service.
1. Turn off air compressor.
2. Disconnect cord from main power supply.
3. Open all drains.
4. Wait for the air compressor to cool before starting service.
MAINTENANCE CHART
PROCEDURE DAILY WEEKLY MONTHLY 200 HOURS
Xlevel lio pmup kcehC
Xnoitcepsni kael liO
Drain condensation in air tank(s) X
Check for unusual noise/vibration X
Xskael ria rof kcehC
X retlif ria tcepsnI
X rosserpmoc fo roiretxe naelC
Xevlav feiler ytefas kcehC
Change pump oil* X
Replace air filter X
*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3 months, whichever
comes first. Recommended non-detergent straight weights.
4. START/STOP: Turn to the ON position. This will allow the air compressor to “START” building up pressure in
the air tanks and “STOP” when correct pressure is achieved. When pressure drops with usage, the air
compressor willautomatically “START” building up pressure again.
WARNING: Never assume the air compressor is safe to work on just because
it is not operating. It could restart anytime!